Lesson
1 – NEC 2017 Bonding & Grounding Requirements for Telecommunications
Circuits and Equipment. 4 hours
This lesson covers general
requirements for bonding and grounding of residential and commercial buildings
for the safety and protection of people, buildings and equipment per the NEC:
General
requirements for bonding and grounding per Article 250.
- Grounding of AC electrical systems;
250.4.
- Bonding of electrical equipment;
250.4.
- Effective ground-fault current
path; 250.4.
- Grounding of separately derived
systems; 250.20.C.
- Grounding electrode systems
including ground rings, ground rods and resistance
requirements; 250.52.
- Bonding requirements providing
access for other systems; 250.94.
- Grounding of isolated receptacles;
250.146.D.
- Bonding of the DC power system to
the MGN; 250.168.
Communications
systems bonding and grounding per Article 800.
- Overhead wires and cables outside
and entering buildings; 800.44.
- Cables entering buildings limited
to 50 feet; 800.48.
- Protection device application and
location; 800.90.
- Grounding or interruption of
metallic sheath members; 800.93.
- Protector grounding conductor
material, size and length; 800.100.
- Protector grounding conductor
electrode; 800.100.B.
- Protector grounding at mobile
homes; 800.106.
- Communications cables separation
from electrical cables; 800.133.
- Communications cables voltage
rating; 800.179.
Optical
fiber cables and raceways per Article 770.
- Cables outside and entering
buildings; 770.48.
- Protection device application and
location; 770.93.
- Grounding or interruption of
metallic sheath members; 770.100
Lesson
2 – NESC and RUS Bonding & Grounding Requirements
for
Telecommunications Outside Plant and Central Offices 4 hours
This
lesson covers general requirements for bonding and grounding telecommunications
Outside Plant and Central Office cables and equipment for the safety and
protection of people, buildings and equipment per the NESC (National Electric
Safety Code) and RUS (Rural Utilities Service):
NESC
requirements for bonding and grounding.
- MGN grounding conductor as point of
connection; 092.
- Ground rod requirements; 094.B
- Ground rod resistance requirements;
096
- Bonding of electrodes; 099.C
- Clearance between AC power lines
and communication lines 235.C and Table 235-5.
RUS
requirements for bonding and grounding.
- Grounding and bonding of
communications apparatus; 384.C.
- Shielding, grounding and equalization
methods; 1751F-801 pg-26.
- Solid-State electronic equipment
protection; 1751F-801 pg-30.
- Gas tube protection of electrical
circuits; 1751F-801 pg-34.
- Ground electrodes, requirements and
alternatives; 1751F-802 pg-9.
- Design of a Central Office grounding
systems; 1751F-802 pg-19.
- Central Office ground system resistance
objectives; 1751F-802 pg-24.
- Central Office Master Ground Bar
Description; 1751F-810 pg-10.
- Radio/Microwave tower and fence
grounding; 1751F-810 pg-12.
- Central Office ground window bar;
1751F-810 pg-15.
- Central Office isolated ground zone;
1751F-810 pg-17.
- Main Distributing Frame grounding
requirements; 1751F-810 pg-17.
- Grounding cable sizing, routing and
terminating; 1751F-801 pg-22.